◆ Pure sine wave output.
◇ Wide AC voltage input range, AVR output.
◆ Adopt traditional EI transformer , stable performance.
◇ LCD/LED&LCD real-time display, concise and straightforward.
◆ Working modes: AC first or battery first optional, intelligent charging.
◇ Built-in MPPT or PWM charge controller optional.
◆ RS232 communication port optional.
Product Parameters |
||||
Specification |
||||
Model: |
4000 48/96V |
5000 48/96V |
6000 48/96V |
|
Rated Power |
4000W |
5000W |
6000W |
|
Battery Voltage |
48V/96V |
|||
Size(L*W*Hmm) |
460*245*445 |
|||
Packing Size(L*W*Hmm) |
530*310*550 |
|||
N.W.(kg) |
46 |
52 |
53 |
|
G.W.(kg) |
48(Carton Packing) |
58(Wooden Packing) |
59(Wooden Packing) |
|
Parameters |
||||
Input |
Voltage Range |
73VAC~138VAC / 76VAC~144VAC / 79VAC~150VAC / 145VAC~275VAC / 152VAC~288VAC / 158VAC~300VAC |
||
Frequency Range |
45Hz~64Hz |
|||
Output |
Voltage Range |
110VAC±2% / 115VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% (Battery Mode) |
||
Frequency Range |
50Hz±0.5 or 60Hz±0.5 |
|||
Output Wave |
Pure Sine Wave |
|||
Total Harmonic Distortion |
≤3% |
|||
Transfer Time |
≤4ms |
|||
Efficiency |
≥85% |
|||
Working Mode |
Battery First/AC First/Saving Energy Mode |
|||
AC Charging current |
Max 15A |
|||
Inside Solar controller |
Charging Mode |
PWM / MPPT |
||
Charging current |
48V System: 10A,20A,30A,40A,50A,60A;96V System: 50A,100A |
|||
PV Input Voltage Range |
48V System: 60V-88V; 96V System: 120V-176V |
|||
Max PV Input Voltage(At 25℃) |
48V System:100V; 96V System:200V |
|||
PV Array Maximum Power |
48V System:560W,1120W,1680W,1120W,2240W,3360W; 96V System:5.6KW,11.2KW |
|||
Battery Type |
According to Customer Requirements |
|||
Display |
LCD |
|||
Thermal method |
Cooling fan in intelligent control |
|||
Communication |
RS232(Optional) |
|||
Protection |
Over-load |
Overload exceeds 110%,automatic shutdown in 30 secs;Overload exceeds 120%,automatic shutdown in 2 secs(Under mains supply mode, it will not shutdown if overload, just keeping sound) |
||
Short circuit |
Output short-circuit, automatic shutdown after keeping sound 20 secs |
|||
Battery |
High or low voltage protection |
|||
Reverse Polarity |
Reverse Polarity protection(Optional) |
|||
Environment |
Noise |
≤55dB |
||
Temperature |
-10℃~40℃ |
|||
Humidity |
0%~95%(No condense) |
|||
Alarm |
A |
Under normal working situation, buzzer without alarm sound |
||
B |
When battery are fault or under overload protection, buzzer keeping sound 4 times each second |
|||
C |
When inverter starts in normal situation, buzzer reminds 5 times |
|||