HOME > Products > Solar Inverter
Low Frequency Solar hybrid Inverter Company
Product Description

 

Pure sine wave output.                                          
Wide AC voltage input range, AVR output.
Adopt traditional EI transformer , stable performance.
LCD/LED&LCD real-time display, concise and straightforward.
Working modes: AC first or battery first optional, intelligent charging.
Built-in MPPT or PWM charge controller optional.
RS232 communication port optional.

 

Product Parameters 

         

Specification 

Model: 

4000 48/96V

5000 48/96V

6000 48/96V

Rated Power

4000W

5000W

6000W

Battery Voltage

48V/96V  

Size(L*W*Hmm)

460*245*445

Packing Size(L*W*Hmm)

530*310*550

N.W.(kg)

46

52

53

G.W.(kg)

48(Carton Packing)

58Wooden Packing

59Wooden Packing

Parameters

Input

Voltage Range

73VAC~138VAC / 76VAC~144VAC / 79VAC~150VAC / 145VAC~275VAC / 152VAC~288VAC / 158VAC~300VAC

Frequency Range

45Hz~64Hz

Output

Voltage Range

110VAC±2% / 115VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% Battery Mode

Frequency Range

50Hz±0.5 or 60Hz±0.5

Output Wave

Pure Sine Wave

Total Harmonic Distortion

≤3%

Transfer Time

≤4ms

Efficiency

≥85%

Working Mode

Battery First/AC First/Saving Energy Mode

AC Charging current

Max 15A

Inside Solar controller
(Optional)

Charging Mode

PWM / MPPT

Charging current

48V  System: 10A,20A,30A,40A,50A,60A96V System: 50A,100A

PV Input Voltage Range

48V System: 60V-88V; 96V System: 120V-176V

Max PV Input Voltage(At 25)

48V System100V; 96V System200V

PV Array Maximum Power

48V System560W,1120W,1680W,1120W,2240W,3360W; 96V System5.6KW,11.2KW

Battery Type

According to Customer Requirements

Display

LCD

Thermal method

Cooling fan in intelligent control

Communication

RS232Optional

Protection

Over-load 

Overload exceeds 110%automatic shutdown in 30 secsOverload exceeds 120%automatic shutdown in 2 secs(Under mains supply mode, it will not shutdown if overload, just keeping sound)

 Short circuit

Output short-circuit, automatic shutdown after keeping sound 20 secs

Battery

High or low voltage protection

Reverse Polarity

Reverse Polarity protectionOptional

Environment

Noise

≤55dB

Temperature

-10~40

Humidity

0%~95%No condense

Alarm

A

Under normal working situation, buzzer without alarm sound

B

When battery are fault or under overload protection, buzzer keeping sound 4 times each second

C

When inverter starts in normal situation, buzzer reminds 5 times

Note: All specifications are subject to charge without prior notice

Send A Message

Email :

Message :

Code :

lf you have questions or suggestions, please leave us a message, we will reply you as soon as we can!
Previous: Hybrid Inverter Price Next: Growatt on grid solar inverter DC AC MOD 3KW-15KTL-X/XH 3KW 4KW 5KW 6KW 7KW 8KW 9KW 10kw 11KW 12KW 13KW 14KW 15kw